Difference between revisions of "Ssacli ctrl all show config"
Jump to navigation
Jump to search
Line 45: | Line 45: | ||
physicaldrive 2I:3:8 (port 2I:box 3:bay 8, SATA SSD, 480 GB, OK) | physicaldrive 2I:3:8 (port 2I:box 3:bay 8, SATA SSD, 480 GB, OK) | ||
Array B (SATA, Unused Space: 0 MB) | Array B (SATA, Unused Space: 0 MB) | ||
− | logicaldrive 2 (7.28 TB, RAID 50, OK) | + | logicaldrive 2 (7.28 TB, [[RAID 50]], OK) |
physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SATA HDD, 2 TB, OK) | physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SATA HDD, 2 TB, OK) | ||
physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SATA HDD, 2 TB, OK) | physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SATA HDD, 2 TB, OK) |
Latest revision as of 08:35, 21 September 2020
ssacli ctrl all show config
HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) (sn: XTYHC5DRHBI8TU)
Internal Drive Cage at Port 1I, Box 3, OK
Internal Drive Cage at Port 2I, Box 3, OK
Port Name: 1I (Mixed)
Port Name: 2I (Mixed)
Array A (Solid State SATA, Unused Space: 205 MB)
logicaldrive 1 (894.00 GB, RAID 0, OK)
physicaldrive 2I:3:7 (port 2I:box 3:bay 7, SATA SSD, 480 GB, OK)
physicaldrive 2I:3:8 (port 2I:box 3:bay 8, SATA SSD, 480 GB, OK)
Array B (SATA, Unused Space: 0 MB)
logicaldrive 2 (9.10 TB, RAID 5, OK)
physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SATA HDD, 2 TB, OK)
physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SATA HDD, 2 TB, OK)
physicaldrive 1I:3:3 (port 1I:box 3:bay 3, SATA HDD, 2 TB, OK)
physicaldrive 1I:3:4 (port 1I:box 3:bay 4, SATA HDD, 2 TB, OK)
physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SATA HDD, 2 TB, OK)
physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SATA HDD, 2 TB, OK)
SEP (Vendor ID HPE, Model Smart Adapter) 349 (WWID: 21402ET012599B10, Port: Unknown)
ssacli ctrl all show config
HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) (sn: TEYHC0DRHCO0TN) Internal Drive Cage at Port 1I, Box 3, OK Internal Drive Cage at Port 2I, Box 0, OK Port Name: 1I (Mixed) Port Name: 2I (Mixed) Array A (SAS, Unused Space: 0 MB) logicaldrive 1 (279.37 GB, RAID 1, OK) physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SAS HDD, 300 GB, OK) physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SAS HDD, 300 GB, OK) SEP (Vendor ID HPE, Model Smart Adapter) 379 (WWID: 51402EC013D2A5xx, Port: Unknown)
ssacli ctrl all show config HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) (sn: PEYHC0DRHBI4TT) Internal Drive Cage at Port 1I, Box 3, OK Internal Drive Cage at Port 2I, Box 3, OK Port Name: 1I (Mixed) Port Name: 2I (Mixed) Array A (Solid State SATA, Unused Space: 0 MB) logicaldrive 1 (447.10 GB, RAID 1, OK) physicaldrive 2I:3:7 (port 2I:box 3:bay 7, SATA SSD, 480 GB, OK) physicaldrive 2I:3:8 (port 2I:box 3:bay 8, SATA SSD, 480 GB, OK) Array B (SATA, Unused Space: 0 MB) logicaldrive 2 (7.28 TB, RAID 50, OK) physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SATA HDD, 2 TB, OK) physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SATA HDD, 2 TB, OK) physicaldrive 1I:3:3 (port 1I:box 3:bay 3, SATA HDD, 2 TB, OK) physicaldrive 1I:3:4 (port 1I:box 3:bay 4, SATA HDD, 2 TB, OK) physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SATA HDD, 2 TB, OK) physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SATA HDD, 2 TB, OK) SEP (Vendor ID HPE, Model Smart Adapter) 379 (WWID: 51402EC012783D60, Port: Unknown)
Activities[edit]
- Review array output configuration and try to understand it
Related commands[edit]
See also[edit]
- RAID, Disk arrays, HPE SSA,
mdadm
, LVM, ZFS - HPE Proliant: HPE ProLiant Smart Array Controllers, iLO, DL380, DL560, DL580,
ssacli [ show config | show status | show detail ]
, POST code,hponcfg
,amsd
, SPP
Text is available under the Creative Commons Attribution-ShareAlike License; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Source: Wikiversity
Advertising: