Multipath
Jump to navigation
Jump to search
↑ https://www.thegeekdiary.com/understanding-the-dm-multipath-configuration-file-etc-multipath-conf/
↑ https://en.wikipedia.org/wiki/Linux_DM_Multipath
https://en.wikipedia.org/wiki/Linux_DM_Multipath https://linux.die.net/man/8/multipath
mpathconf
multipath -l
multipath -ll
multipath -ll DEVICE_NAME
multipath -t
-t
Display the currently used multipathd configuration
multipathd show config
- Ubuntu:
multipath-tools
package- Binaries:
multipath
multipathd
mpathpersist
- Binaries:
- RHEL:
device-mapper-multipath
package
Config files:
/etc/multipath.conf
[1]https://manpages.debian.org/unstable/multipath-tools/multipath.conf.5.en.html
/etc/multipath/wwids
- multipath -w 3600a09803831417a5a244f5665797a48
- wwid '3600a09803831417a5a244f5665797a48' removed
multipath -W successfully reset wwids
Configuration file: /etc/multipath.conf [2]
- System level defaults (defaults): User can override system level defaults.
- Blacklisted devices (blacklist): User specifies the list of devices that is not to be under the control of DM-MPIO.
- Blacklist exceptions (blacklist_exceptions): Specific devices to be treated as multipath devices even if listed in the blacklist.
- Storage controller specific settings (devices): User specified configuration settings will be applied to devices with specified "Vendor" and "Product" information.
- Device specific settings (multipaths): Fine tune the configuration settings for individual LUNs.
Routing policies implemented: failover, multibus and group_by_serial
- failover : 1 path per priority group. IO thus get routed to one path only.
- multibus : 1 priority group containing all paths to the LU. Brings the maximum spreading, but assumes that all paths are excitable without penalty.
- group_by_serial : 1 priority group per storage controller (serial), paths through one controller are assigned to the associated PG. This policy applies to controllers that impose a latency penalty on LU management hand-over between a pair of redundant controllers.
To modify a policy for device major 8 and minor:
multipath -p multibus -D 8 0
Readings
- Varoqui, C. (2010.) The Linux multipath implementation. Retrieved from http://christophe.varoqui.free.fr/refbook.html
- Changelog: https://git.opensvc.com/?p=multipath-tools/.git;a=log
Activities
- Review
no_path_retry
configuration options in multipath.conf to avoid pvs to hang : https://www.suse.com/support/kb/doc/?id=7022310 - Multipath: remove multipath device unpresented to host
See also
- EMC
powerpath
kpartx
- Fibre Channel: SAN, HBA, LUN, WWN, WWPN, LIF,
rescan-scsi-bus.sh
- Block devices:
blkid
(UUID),lshw -class disk
,hwinfo --disk
,udevadm
,rescan-scsi-bus.sh
,LUN
,hdparm
,findfs
, Add a new disk lsblk
,pvscan
lspci
,lsscsi
,smartctl
,fdisk
,parted
,Kpartx
,pvdiplay
,pvs
,udisksctl
,/dev/sd, nvme list
- LVM: LVM errors LVM scan commands
lkvmetad
, Add a new disk
- scan:
pvscan
vgscan
- LVM:
lvs
lvmscan
lvm fullreport
lvmreport
lvmconfig
lvmdump
lvmcheck
lvm dumpconfig
- Scan:
pvs
vgs
lvs
pvscan
vgscan
- PV:
pvcreate
pvremove
pvscan
pvremove
pvscan
pvs
pvchange
pvck
pvdisplay
pvresize
- LV:
lvdisplay
lvcreate
lvremove
,lvresize
,lvextend
,lvreduce
,lvrename
- VG:
vgdisplay
,vgcreate
,vgremove
,vgextend
,vgreduce
,vgscan
,vgchange
,vgrename
,vgcfgbackup
,vgcfgrestore
,vgimportclone
,vgck
- Check commands:
pvck
vgck
Advertising: