Difference between revisions of "HPE ProLiant"
Jump to navigation
Jump to search
(23 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | [[wikipedia:ProLiant | + | [[wikipedia:ProLiant]] is a popular [[x86]] brand of [[server]] computers sell by HP with advanced features: |
* Redundant and hot swappable [[power supplies]]<ref>https://www.tomshardware.com/news/why-power-supplies-fail-psus,36712.html</ref> | * Redundant and hot swappable [[power supplies]]<ref>https://www.tomshardware.com/news/why-power-supplies-fail-psus,36712.html</ref> | ||
* [[Disk array controller]]s<ref>https://en.wikipedia.org/wiki/Disk_array_controller</ref> with hot swap disks: [[HPE ProLiant Smart Array Controllers]] | * [[Disk array controller]]s<ref>https://en.wikipedia.org/wiki/Disk_array_controller</ref> with hot swap disks: [[HPE ProLiant Smart Array Controllers]] | ||
Line 7: | Line 7: | ||
HP provide drivers a software for managing servers such as '''Management Component Pack''' which includes <ref>https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fb17bc1279ff4900a5e5ca4c2a&swEnvOid=4248#tab3</ref> | HP provide drivers a software for managing servers such as '''Management Component Pack''' which includes <ref>https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fb17bc1279ff4900a5e5ca4c2a&swEnvOid=4248#tab3</ref> | ||
− | * HP online configuration utility (hponcfg) | + | * HP online configuration utility ([[hponcfg]]) |
* Agentless Management Service amsd | * Agentless Management Service amsd | ||
− | * Smart Storage Administrator (SSA): <code>[[ssa]]</code><ref>https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c04455150</ref> | + | * [[Smart Storage Administrator]] (SSA): <code>[[ssa]]</code><ref>https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c04455150</ref> |
* Smart Storage Administrator (SSA) CLI:<code>[[ssacli]]</code><ref>https://wiki.phoenixlzx.com/page/ssacli/</ref> | * Smart Storage Administrator (SSA) CLI:<code>[[ssacli]]</code><ref>https://wiki.phoenixlzx.com/page/ssacli/</ref> | ||
− | * Smart Storage Administrator Diagnostic Utility (SSADU) CLI ssaducli. | + | * Smart Storage Administrator Diagnostic Utility (SSADU) CLI: <code>[[ssaducli]]</code>. |
− | To install them follow installation instructions<ref>https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fb17bc1279ff4900a5e5ca4c2a&swEnvOid=4248#tab3</ref>: <code>apt-get install hponcfg amsd ssa ssacli ssaducli</code> | + | To install them follow installation instructions<ref>https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fb17bc1279ff4900a5e5ca4c2a&swEnvOid=4248#tab3</ref>: <code>apt-get install [[hponcfg]] [[amsd]] [[ssa]] [[ssacli]] [[ssaducli]]</code> |
Binaries provides by <code>amsd</code> package: <code>amsd_rev amsd smad cpqiScsi smad_rev ahslog mr_cpqScsi</code> | Binaries provides by <code>amsd</code> package: <code>amsd_rev amsd smad cpqiScsi smad_rev ahslog mr_cpqScsi</code> | ||
== Models == | == Models == | ||
− | * [[DL380]] (up to 2 [[processors]]) | + | * [[DL360]] |
− | * [[DL580]] (up to 4 [[processors]]). See also [[Dell PowerEdge]] R940. | + | * [[DL380]] 2U (up to 2 [[processors]]) |
+ | * [[DL560]] 2U (up to 4 [[processors]]) | ||
+ | * [[DL580]] 4U (up to 4 [[processors]]). See also [[Dell PowerEdge]] R940. | ||
* [[DL980]] | * [[DL980]] | ||
* [[Lenovo ThinkSystem]] SR950 (up to 8 [[processors]], up to 28x cores per processor. Total: 224 cores) | * [[Lenovo ThinkSystem]] SR950 (up to 8 [[processors]], up to 28x cores per processor. Total: 224 cores) | ||
+ | |||
+ | == Timeline == | ||
+ | https://en.wikipedia.org/wiki/ProLiant#Timeline | ||
+ | * 2017 Gen 10 | ||
+ | * 2014 Gen 9 | ||
+ | * 2012 Gen 8 | ||
== Related terms == | == Related terms == | ||
Line 27: | Line 35: | ||
* [[HPE Synergy]] | * [[HPE Synergy]] | ||
* [[HPE Fast Fault Tolerance]], [[A3DC]] | * [[HPE Fast Fault Tolerance]], [[A3DC]] | ||
+ | * [[HPE ProLiant Smart Array Controllers]] | ||
+ | * [[HPE OneView]] | ||
+ | * [[Redfish (specification)]] | ||
+ | * [[POST code]] | ||
+ | * [[LAN on motherboard (LOM)]] | ||
== Activities == | == Activities == | ||
# Read about different Proliant models and other competitors such as: [[Dell]], [[IBM]] or [[Supermicro]]. | # Read about different Proliant models and other competitors such as: [[Dell]], [[IBM]] or [[Supermicro]]. | ||
− | # Identify characteristics of most popular models: [[DL380]] (up to 2 CPUs/24-[[DIMM]] slots) and [[ | + | # Identify characteristics of most popular models: [[DL380]] (up to 2 CPUs/24-[[DIMM]] slots) and [[DL580]]. |
## Read [[DL380 Gen10]] QuickSpecs: https://h20195.www2.hpe.com/v2/getdocument.aspx?docname=a00008180enw | ## Read [[DL380 Gen10]] QuickSpecs: https://h20195.www2.hpe.com/v2/getdocument.aspx?docname=a00008180enw | ||
## Read DL380 Gen10 User Guide: https://h20628.www2.hp.com/km-ext/kmcsdirect/emr_na-a00019109en_us-11.pdf | ## Read DL380 Gen10 User Guide: https://h20628.www2.hp.com/km-ext/kmcsdirect/emr_na-a00019109en_us-11.pdf | ||
Line 37: | Line 50: | ||
# Use your browser to [[/Access to iLO/]] | # Use your browser to [[/Access to iLO/]] | ||
# [[/Remove a disk from your redundant storage array and review OS logs/]] and verify output from <code> ssacli ctrl slot=0 pd all show status</code> | # [[/Remove a disk from your redundant storage array and review OS logs/]] and verify output from <code> ssacli ctrl slot=0 pd all show status</code> | ||
− | # Read page about [[ | + | # Read page about [[HPE ProLiant Smart Array Controllers]] |
− | # Enter HP Proliant iLO SSA | + | # Enter [[HP Proliant iLO SSA]] (Smart Storage Administrator) application by pressing <code>[[F9]]</code> and configure your [[disk array]]. |
# Learn about [[UEFI]] System Utilities User Guide for HPE ProLiant Gen10 https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00016407ja_jp | # Learn about [[UEFI]] System Utilities User Guide for HPE ProLiant Gen10 https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00016407ja_jp | ||
# Learn about HPE Agentless Management: https://buy.hpe.com/us/en/software/server-management-software/server-ilo-management/ilo-management-engine/hpe-agentless-management/p/5219980 | # Learn about HPE Agentless Management: https://buy.hpe.com/us/en/software/server-management-software/server-ilo-management/ilo-management-engine/hpe-agentless-management/p/5219980 | ||
Line 45: | Line 58: | ||
== See also == | == See also == | ||
* {{Proliant}} | * {{Proliant}} | ||
− | |||
− | |||
* {{Computing vendors}} | * {{Computing vendors}} | ||
Line 54: | Line 65: | ||
[[Category:Server software]] | [[Category:Server software]] | ||
[[Category:Computer engineering]] | [[Category:Computer engineering]] | ||
+ | |||
+ | [[Category:Proliant]] | ||
{{CC license}}. Source: https://en.wikiversity.org/wiki/System_administration/ProLiant | {{CC license}}. Source: https://en.wikiversity.org/wiki/System_administration/ProLiant |
Latest revision as of 12:24, 1 July 2022
wikipedia:ProLiant is a popular x86 brand of server computers sell by HP with advanced features:
- Redundant and hot swappable power supplies[1]
- Disk array controllers[2] with hot swap disks: HPE ProLiant Smart Array Controllers
- Out of Band Management capabilities (HP Integrated Lights-Out or iLO)
- UEFI Secure Boot and Secure Start support
- FIPS 140-2 validation
HP provide drivers a software for managing servers such as Management Component Pack which includes [3]
- HP online configuration utility (hponcfg)
- Agentless Management Service amsd
- Smart Storage Administrator (SSA):
ssa
[4] - Smart Storage Administrator (SSA) CLI:
ssacli
[5] - Smart Storage Administrator Diagnostic Utility (SSADU) CLI:
ssaducli
.
To install them follow installation instructions[6]: apt-get install hponcfg amsd ssa ssacli ssaducli
Binaries provides by amsd
package: amsd_rev amsd smad cpqiScsi smad_rev ahslog mr_cpqScsi
Models[edit]
- DL360
- DL380 2U (up to 2 processors)
- DL560 2U (up to 4 processors)
- DL580 4U (up to 4 processors). See also Dell PowerEdge R940.
- DL980
- Lenovo ThinkSystem SR950 (up to 8 processors, up to 28x cores per processor. Total: 224 cores)
Timeline[edit]
https://en.wikipedia.org/wiki/ProLiant#Timeline
- 2017 Gen 10
- 2014 Gen 9
- 2012 Gen 8
Related terms[edit]
- Primary Riser, Secondary Riser
- HPE Synergy
- HPE Fast Fault Tolerance, A3DC
- HPE ProLiant Smart Array Controllers
- HPE OneView
- Redfish (specification)
- POST code
- LAN on motherboard (LOM)
Activities[edit]
- Read about different Proliant models and other competitors such as: Dell, IBM or Supermicro.
- Identify characteristics of most popular models: DL380 (up to 2 CPUs/24-DIMM slots) and DL580.
- Read DL380 Gen10 QuickSpecs: https://h20195.www2.hpe.com/v2/getdocument.aspx?docname=a00008180enw
- Read DL380 Gen10 User Guide: https://h20628.www2.hp.com/km-ext/kmcsdirect/emr_na-a00019109en_us-11.pdf
- Read HP iLO User Guide: https://support.hpe.com/hpsc/doc/public/display?docId=a00074744en_us
- Install latest LTS Ubuntu Server and install HP Management Component Pack
- Use your browser to /Access to iLO/
- /Remove a disk from your redundant storage array and review OS logs/ and verify output from
ssacli ctrl slot=0 pd all show status
- Read page about HPE ProLiant Smart Array Controllers
- Enter HP Proliant iLO SSA (Smart Storage Administrator) application by pressing
F9
and configure your disk array. - Learn about UEFI System Utilities User Guide for HPE ProLiant Gen10 https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00016407ja_jp
- Learn about HPE Agentless Management: https://buy.hpe.com/us/en/software/server-management-software/server-ilo-management/ilo-management-engine/hpe-agentless-management/p/5219980
- Learn about Service Pack for ProLiant (SPP)
See also[edit]
- HPE Proliant: HPE ProLiant Smart Array Controllers, iLO, DL380, DL560, DL580,
ssacli [ show config | show status | show detail ]
, POST code,hponcfg
,amsd
, SPP - Computing vendors: HPE Proliant, Dell PowerEdge, Lenovo ThinkSystem, Supermicro
Text is available under the Creative Commons Attribution-ShareAlike License; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy.. Source: https://en.wikiversity.org/wiki/System_administration/ProLiant
- ↑ https://www.tomshardware.com/news/why-power-supplies-fail-psus,36712.html
- ↑ https://en.wikipedia.org/wiki/Disk_array_controller
- ↑ https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fb17bc1279ff4900a5e5ca4c2a&swEnvOid=4248#tab3
- ↑ https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c04455150
- ↑ https://wiki.phoenixlzx.com/page/ssacli/
- ↑ https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fb17bc1279ff4900a5e5ca4c2a&swEnvOid=4248#tab3
Advertising: