Ssacli ctrl all show config

From wikieduonline
Jump to navigation Jump to search
ssacli ctrl all show config
HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded)  (sn: XTYHC5DRHBI8TU)
  Internal Drive Cage at Port 1I, Box 3, OK
  Internal Drive Cage at Port 2I, Box 3, OK
  Port Name: 1I (Mixed)
  Port Name: 2I (Mixed)
  Array A (Solid State SATA, Unused Space: 205  MB)
     logicaldrive 1 (894.00 GB, RAID 0, OK)
     physicaldrive 2I:3:7 (port 2I:box 3:bay 7, SATA SSD, 480 GB, OK)
     physicaldrive 2I:3:8 (port 2I:box 3:bay 8, SATA SSD, 480 GB, OK)
  Array B (SATA, Unused Space: 0  MB)
     logicaldrive 2 (9.10 TB, RAID 5, OK)
     physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SATA HDD, 2 TB, OK)
     physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SATA HDD, 2 TB, OK)
     physicaldrive 1I:3:3 (port 1I:box 3:bay 3, SATA HDD, 2 TB, OK)
     physicaldrive 1I:3:4 (port 1I:box 3:bay 4, SATA HDD, 2 TB, OK)
     physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SATA HDD, 2 TB, OK)
     physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SATA HDD, 2 TB, OK)
  SEP (Vendor ID HPE, Model Smart Adapter) 349  (WWID: 21402ET012599B10, Port: Unknown)

ssacli ctrl all show config

HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded)  (sn: TEYHC0DRHCO0TN)
   Internal Drive Cage at Port 1I, Box 3, OK
   Internal Drive Cage at Port 2I, Box 0, OK
   Port Name: 1I (Mixed)
   Port Name: 2I (Mixed)
   Array A (SAS, Unused Space: 0  MB)
      logicaldrive 1 (279.37 GB, RAID 1, OK)
      physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SAS HDD, 300 GB, OK)
      physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SAS HDD, 300 GB, OK)
   SEP (Vendor ID HPE, Model Smart Adapter) 379  (WWID: 51402EC013D2A5xx, Port: Unknown)


ssacli ctrl all show config 
HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded)  (sn: PEYHC0DRHBI4TT)
  Internal Drive Cage at Port 1I, Box 3, OK
  Internal Drive Cage at Port 2I, Box 3, OK
  Port Name: 1I (Mixed)
  Port Name: 2I (Mixed)
  Array A (Solid State SATA, Unused Space: 0  MB)
     logicaldrive 1 (447.10 GB, RAID 1, OK)
     physicaldrive 2I:3:7 (port 2I:box 3:bay 7, SATA SSD, 480 GB, OK)
     physicaldrive 2I:3:8 (port 2I:box 3:bay 8, SATA SSD, 480 GB, OK)
  Array B (SATA, Unused Space: 0  MB)
     logicaldrive 2 (7.28 TB, RAID 50, OK)
     physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SATA HDD, 2 TB, OK)
     physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SATA HDD, 2 TB, OK)
     physicaldrive 1I:3:3 (port 1I:box 3:bay 3, SATA HDD, 2 TB, OK)
     physicaldrive 1I:3:4 (port 1I:box 3:bay 4, SATA HDD, 2 TB, OK)
     physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SATA HDD, 2 TB, OK)
     physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SATA HDD, 2 TB, OK)
  SEP (Vendor ID HPE, Model Smart Adapter) 379  (WWID: 51402EC012783D60, Port: Unknown)

Activities[edit]

  1. Review array output configuration and try to understand it


Related commands[edit]

See also[edit]

Text is available under the Creative Commons Attribution-ShareAlike License; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Source: Wikiversity

Advertising: