Difference between revisions of "Ssacli ctrl all show config"

From wikieduonline
Jump to navigation Jump to search
Tags: Mobile web edit, Mobile edit
Tags: Mobile web edit, Mobile edit
Line 1: Line 1:
 
  <code>[[ssacli]] ctrl all show config</code>
 
  <code>[[ssacli]] ctrl all show config</code>
HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded)  (sn: XTYHC5DRHBI8RU)
+
HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded)  (sn: XTYHC5DRHBI8RU)
 
   Internal Drive Cage at Port 1I, Box 3, OK
 
   Internal Drive Cage at Port 1I, Box 3, OK
 
   Internal Drive Cage at Port 2I, Box 3, OK
 
   Internal Drive Cage at Port 2I, Box 3, OK
Line 18: Line 18:
 
       physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SATA HDD, 2 TB, OK)
 
       physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SATA HDD, 2 TB, OK)
 
   SEP (Vendor ID HPE, Model Smart Adapter) 349  (WWID: 21402ET012599B10, Port: Unknown)
 
   SEP (Vendor ID HPE, Model Smart Adapter) 349  (WWID: 21402ET012599B10, Port: Unknown)
</pre>
 
  
 
<code>[[ssacli]] ctrl all show config</code>
 
<code>[[ssacli]] ctrl all show config</code>

Revision as of 13:46, 31 August 2020

ssacli ctrl all show config
HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded)  (sn: XTYHC5DRHBI8RU)
  Internal Drive Cage at Port 1I, Box 3, OK
  Internal Drive Cage at Port 2I, Box 3, OK
  Port Name: 1I (Mixed)
  Port Name: 2I (Mixed)
  Array A (Solid State SATA, Unused Space: 205  MB)
     logicaldrive 1 (894.00 GB, RAID 0, OK)
     physicaldrive 2I:3:7 (port 2I:box 3:bay 7, SATA SSD, 480 GB, OK)
     physicaldrive 2I:3:8 (port 2I:box 3:bay 8, SATA SSD, 480 GB, OK)
  Array B (SATA, Unused Space: 0  MB)
     logicaldrive 2 (9.10 TB, RAID 5, OK)
     physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SATA HDD, 2 TB, OK)
     physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SATA HDD, 2 TB, OK)
     physicaldrive 1I:3:3 (port 1I:box 3:bay 3, SATA HDD, 2 TB, OK)
     physicaldrive 1I:3:4 (port 1I:box 3:bay 4, SATA HDD, 2 TB, OK)
     physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SATA HDD, 2 TB, OK)
     physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SATA HDD, 2 TB, OK)
  SEP (Vendor ID HPE, Model Smart Adapter) 349  (WWID: 21402ET012599B10, Port: Unknown)

ssacli ctrl all show config

HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded)  (sn: PEYHC0DRHCO0BN)
   Internal Drive Cage at Port 1I, Box 3, OK
   Internal Drive Cage at Port 2I, Box 0, OK
   Port Name: 1I (Mixed)
   Port Name: 2I (Mixed)
   Array A (SAS, Unused Space: 0  MB)
      logicaldrive 1 (279.37 GB, RAID 1, OK)
      physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SAS HDD, 300 GB, OK)
      physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SAS HDD, 300 GB, OK)
   SEP (Vendor ID HPE, Model Smart Adapter) 379  (WWID: 51402EC013D2A5xx, Port: Unknown)